2 years warranty
AC input voltage range . . . . . .85~264VAC; 120~370VDC
AC inrush current. . . . . . . . .Cold start, 30A at 115VAC, 60A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~150% hiccup mode, auto-recovery
Over voltage protection. . . . . .115%~135% rated output voltage
Setup, rise, hold up time. . . . .300ms, 50ms, 80ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .0~45°C@100%, -10°C@80%, 60°C@60% load
Safety standards . . . . . . . . .UL1012, UL1950, TUV EN60950 approved
EMC standards. . . . . . . . . . .EN55022 class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11, ENV50204
Connection . . . . . . . . . . . .5P/9.5mm pitch terminal block
Packing. . . . . . . . . . . . . .0.51kg; 24pcs / 13.1kg / 0.75CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10011 |
S-25-5 |
5V, 0~5.0A |
±2% |
50mV |
72% |
10012 |
S-25-12 |
12V, 0~2.1A |
±1% |
100mV |
76% |
10013 |
S-25-15 |
15V,0~1.7A |
±1% |
100mV |
77% |
10014 |
S-25-24 |
24V, 0~1.1A |
±1% |
100mV |
80% |

AC input range selectable by switch
Protections : Short circuit / Over load / Over voltage
Fixed switching frequency at 83 KHz
Approvals : UL / TUV / CB / CE
Cooling by free air convection
100% full load burn-in test
2 years warranty
AC input voltage range . . . . . .88~132VAC/ 176~264VAC selectable by switch
AC inrush current. . . . . . . . .Cold start, 30A at 115VAC, 60A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~150% hiccup mode, auto-recovery
Over voltage protection. . . . . .115%~135% rated output voltage
Setup, rise, hold up time. . . . .1000ms, 30ms, 15ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .-10~60°C (refer to output derating curve)
Safety standards . . . . . . . . .UL1012, TUV EN60950 approved
EMC standards. . . . . . . . . . .EN55022 class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11, ENV50204
Connection . . . . . . . . . . . .7P/9.5mm pitch terminal block
Packing. . . . . . . . . . . . . .0.65kg; 20pcs / 14.2kg / 0.89CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10031 |
S-40-5 |
5V, 0~8.0A |
±2% |
75mV |
72% |
10032 |
S-40-12 |
12V, 0~3.5A |
±1% |
100mV |
76% |
10033 |
S-40-15 |
15V,0~2.8A |
±1% |
100mV |
76% |
10034 |
S-40-24 |
24V, 0~1.8A |
±1% |
100mV |
78% |

Universal AC input / Full range
Protections : Short circuit / Over load / Over voltage
Fixed switching frequency at 50 KHz
Approvals : UL / CUL / TUV / CB / CE
Cooling by free air convection
100% full load burn-in test
2 years warranty
AC input voltage range . . . . . .85~264VAC; 120~370VDC
AC inrush current. . . . . . . . .Cold start, 30A at 115VAC, 60A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~150% hiccup mode, auto-recovery
Over voltage protection. . . . . .115%~135% rated output voltage
Setup, rise, hold up time. . . . .300ms, 50ms, 80ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .0~45°C@100%, -10°C@80%, 60°C@60% load
Safety standards . . . . . . . . .UL1012, UL1950, TUV EN60950 approved
EMC standards. . . . . . . . . . .EN55022 class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11, ENV50204
Connection . . . . . . . . . . . .5P/9.5mm pitch terminal block
Packing. . . . . . . . . . . . . .0.51kg; 24pcs / 13.1kg / 0.75CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10051 |
S-60-5 |
5V, 0~12A |
±2% |
120mV |
73% |
10052 |
S-60-12 |
12V, 0~5.0A |
±1% |
120mV |
76% |
10053 |
S-60-15 |
15V,0~4.0A |
±1% |
150mV |
77% |
10054 |
S-60-24 |
24V, 0~2.5A |
±1% |
150mV |
79% |

AC input range selectable by switch
Protections : Short circuit / Over load / Over voltage
Fixed switching frequency at 83 KHz
Approvals : UL / TUV / CB / CE
Cooling by free air convection
100% full load burn-in test
2 years warranty
AC input voltage range . . . . . .88~132VAC/ 176~264VAC selectable by switch
AC inrush current. . . . . . . . .Cold start, 30A at 115VAC, 60A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~150% hiccup mode, auto-recovery
Over voltage protection. . . . . .115%~135% rated output voltage
Setup, rise, hold up time. . . . .1000ms, 30ms, 15ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .-10~60°C (refer to output derating curve)
Safety standards . . . . . . . . .UL1012, TUV EN60950 approved
EMC standards. . . . . . . . . . .EN55022 class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11, ENV50204
Connection . . . . . . . . . . . .7P/9.5mm pitch terminal block
Packing. . . . . . . . . . . . . .0.65kg; 20pcs / 14.2kg / 0.89CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10071 |
S-100F-5 |
5V, 0~20A |
±2% |
100mV |
76% |
10072 |
S-100F-7.5 |
7.5V, 0~13.5A |
±1% |
125mV |
78% |
10073 |
S-100F-12 |
12V,0~8.5A |
±1% |
125mV |
80% |
10074 |
S-100F-15 |
15V, 0~6.7A |
±1% |
125mV |
81% |
10075 |
S-100F-24 |
24V, 0~4.5A |
±1% |
150mV |
83% |
10076 |
S-100F-48 |
48V, 0~2.2A |
±1% |
150mV |
84% |

AC input range selectable by switch
Protections : Short circuit / Over load / Over voltage
Fixed switching frequency at 25 KHz
Approvals : UL / CUL / TUV / CB / CE
Cooling by free air convection
100% full load burn-in test
2 years warranty
AC input voltage range . . . . . .88~132VAC/ 176~264VAC selectable by switch
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~150% shut off, AC recycle to re-start
Over voltage protection. . . . . .115%~145% rated output voltage
Setup, rise, hold up time. . . . .100ms, 50ms, 20ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .-10~60°C (refer to output derating curve)
Safety standards . . . . . . . . .UL1012, UL1950, TUV EN60950 approved
EMC standards. . . . . . . . . . .EN55022 class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11, ENV50204
Connection . . . . . . . . . . . .7P/9.5mm pitch terminal block
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10081 |
S-150-5 |
5V, 0~30A |
±2% |
150mV |
78% |
10082 |
S-150-7.5 |
7.5V, 0~20A |
±1% |
150mV |
80% |
10083 |
S-150-9 |
9V,0~16.7A |
±1% |
180mV |
80% |
10084 |
S-150-12 |
12V, 0~12.5A |
±1% |
180mV |
82% |
10088 |
S-150-13.5 |
13.5V, 0~11.2A |
±1% |
180mV |
83% |
10085 |
S-150-15 |
15V, 0~10A |
±1% |
180mV |
84% |
10086 |
S-150-24 |
24V,0~6.5A |
±1% |
240mV |
85% |
10089 |
S-150-27 |
27V, 0~5.6A |
±1% |
240mV |
86% |
10087 |
S-150-48 |
48V, 0~3.2A |
±1% |
240mV |
87% |
* Another SC model with constant current limiting & temperature compensation circuit. |

AC input range auto sensing
Built-in passive PFC choke
Protections : Short circuit / Over load / Over voltage / Over temp.
Fixed switching frequency at 75 KHz
Force air cooling by built-in DC fan
Approvals : UL / CUL / TUV / CB / CE
Cooling fan ON/OFF auto control
100% full load burn-in test
2 years warranty
AC input voltage range . . . . . .88~132VAC/ 176~264VAC auto-sensing
AC inrush current. . . . . . . . .Cold start, 18A at 115VAC, 36A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~135% hiccup mode, auto-recovery
Over voltage protection. . . . . .115%~150% rated output voltage
Setup, rise, hold up time. . . . .1000ms, 20ms, 20ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .0~50°C@100%, -10°C@80%, 60°C@60% load
Safety standards . . . . . . . . .UL1950, TUV EN60950 approved
(7.5V design refer to UL1950)
EMC standards. . . . . . . . . . .EN55022 class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11, ENV50204
Connection . . . . . . . . . . . .7P/9.5mm pitch terminal block with cover
Packing. . . . . . . . . . . . . .1.2kg; 12pcs / 15.3kg / 0.9CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10101 |
S-240-5 |
5V, 0~40A |
±2% |
150mV |
78% |
10102 |
S-240-7.5 |
7.5V, 0~30A |
±2% |
200mV |
80% |
10103 |
S-240-12 |
12V,0~18A |
±1% |
150mV |
82% |
10104 |
S-240-15 |
15V, 0~15A |
±1% |
150mV |
83% |
10105 |
S-240-24 |
24V, 0~10A |
±1% |
180mV |
84% |
10106 |
S-240-30 |
30V,0~8.0A |
±1% |
180mV |
85% |
10107 |
S-240-48 |
48V, 0~5.0A |
±1% |
240mV |
87% |

AC input range selectable by switch
Protections : Short circuit / Over load / Over voltage
Force air cooling by built-in DC fan
Fixed switching frequency at 60 KHz
100% full load burn-in test
Low cost, high reliability
2 years warranty
AC input voltage range . . . . . .90~132VAC/ 176~264VAC selectable by switch
AC inrush current. . . . . . . . .Cold start, 50A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~135% hiccup mode, auto-recovery
Setup, rise, hold up time. . . . .800ms, 50ms, 16ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .-10~50°C@100%, 60°C@60% load
Safety standards . . . . . . . . .UL60950 approved
EMC standards. . . . . . . . . . .Design refer to EN55022 class B
Connection . . . . . . . . . . . .9P/9.5mm pitch terminal block with cover
Packing. . . . . . . . . . . . . .1.3kg; 8pcs / 11.0kg / 0.97CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10651 |
S-250-5 |
5V, 0~40A |
±2% |
80mV |
74.0% |
10652 |
S-250-12 |
12V, 0~18A |
±1% |
120mV |
79.0% |
10653 |
S-250-15 |
15V,0~15A |
±1% |
120mV |
80.0% |
10654 |
S-250-24 |
24V, 0~10A |
±1% |
120mV |
81.5% |
10655 |
S-250-27 |
27V,0~9.0A |
±1% |
150mV |
82.0% |
10656 |
S-250-48 |
48V, 0~5.2A |
±1% |
200mV |
82.0% |

AC input range selectable by switch
Protections : Short circuit / Over load / Over voltage / Over temp.
Fixed switching frequency at 90 KHz
Force air cooling by built-in DC fan
Cooling fan ON/OFF auto control
Approvals : UL / CUL
100% full load burn-in test
2 years warranty
AC input voltage range . . . . . .88~132VAC/ 176~264VAC selectable by switch
AC inrush current. . . . . . . . .Cold start, 20A at 115VAC, 40A at 230VAC
DC adjustment range. . . . . . . .±10% rated output voltage
Over load protection . . . . . . .105%~135% hiccup mode, auto-recovery
Over voltage protection. . . . . .115%~145% rated output voltage
Setup, rise, hold up time. . . . .2000ms, 20ms, 20ms at full load and 230VAC
Withstand voltage. . . . . . . . .I/P-O/P:3KVAC, I/P-FG:1.5KVAC, 1minute
Working temperature. . . . . . . .0~40°C@100%, -10°C@80%, 60°C@60% load
Safety standards . . . . . . . . .UL1950 approved
Connection . . . . . . . . . . . .9P/9.5mm pitch terminal block with cover
Packing. . . . . . . . . . . . . .1.08kg; 12pcs / 13.8kg / 0.98CUFT
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
10111 |
S-320-5 |
5V, 0~50A |
±2% |
150mV |
77% |
10112 |
S-320-7.5 |
7.5V, 0~36A |
±2% |
150mV |
80% |
10113 |
S-320-12 |
12V,0~25A |
±1% |
150mV |
82% |
10114 |
S-320-13.5 |
13.5V, 0~22A |
±1% |
150mV |
83% |
10115 |
S-320-15 |
15V, 0~20A |
±1% |
150mV |
84% |
10116 |
S-320-24 |
24V, 0~12.5A |
±1% |
150mV |
86% |
10117 |
S-320-27 |
27V, 0~11A |
±1% |
200mV |
86% |
10118 |
S-320-48 |
48V, 0~6.5A |
±1% |
240mV |
87% |